Refrigerant Accumulator & Oil Separator

Quantity:

  • SAV-Series RA-Series S-Series
  • GITTA
S Series Oil Separator
SEPARATOR’S FUNCTION IS TO HELP REFRIGERATION AND AIR CONDITIONING
   SYSTEMS OPERATE MORE EFFICIENTLY AND SAVE ENERGY.

IN ANY REFRIGERATION SYSTEM, REFRIGERANT AND OIL ARE ALWAYS PRESENT.
CERTAIN AMOUNTS OF OIL WILL ALWAYS LEAVE THE COMPRESSOR CRANKCASE
   WITH REFRIGERANT GAS.

THE OIL SEPARATOR SEPARATES THE OIL FROM THE REFRIGERANT AND
   RETURNS IT TO THE COMPRESSOR CRANK-CASE BEFORE IT CAN ENTER OTHER
   COMPONENTS OF THE SYSTEM.

THE LESS OIL IN CIRCULATION IN A REFRIGERATION SYSTEM, THE MORE
   REFRIGERANT AVAILABLE FOR COOLING.

THIS INCREASES THE EFFICIENCY OF A SYSTEM BY REDUCING RUNNING TIME
   AND LOWERING OPERATING COST.

SAFE WORKING PRESSURE-450PSI. 
----------------------------------------------------------------------------------------------------------------------------------------
SAV Series
Refrigerant Heat Exchanger-Suction Accumulator

IT’S INCLUDED WITH HIGH-TENSION AND LOW-TENSION REFRIGERANTS IN ONE AC
   SYSTEM. HIGH-TENSION IS WITH HIGHER TEMPERATURE WHICH NEEDS TO BE
   COOL THROUGH REFRIGERATION.
→LOW-TENSION REFRIGERANT IS WITH LOWER TEMPERATURE WHICH NEEDS THE
   SEPARATORS TO ISOLATE LIQUID AND GASIFY REFRIGERANT.
→FOR AVOIDING LIQUID COMPRESSED, LIQUID REFRIGERANT NEEDS SOME TIME AS
   WELL AS SOME TEMPERATURE TO EVAPORATE AND TO BE GASIFIED BEFORE IT
   FLOWS INTO ONE COMPRESSOR.
→THE FUNCTION OF EXCHANGER IS TO COLLECTING THE ABOVE MENTIONED
   REFRIGERANTS INTO ONE CONTAINER.
→THE EFFICIENCY OF WHOLE SYSTEM CAN ACHIEVE THE BEST COOLING EFFECT
   BY THIS RECIPROCAL HEATING INTERACTION.
→WE OFFER THE COMPLETE LINE OF STRONG CONSTRUCTION OF SUCTION
   ACCUMULATORS WHICH PROVIDE YOU WITH THE LARGEST CAPACITY OF
   PROTECTION AGAINST RUST.
→ALL HEAT EXCHANGER-SUCTION ACCUMULATORS ARE COMPLETE WITH RR 362
   FUSIBLE PLUG INSTALLED.
→PLEASE REFER TO ABOVE-LISTED SPECIFICATIONS WHILE ORDERING.


----------------------------------------------------------------------------------------------------------------------------------------
RA Series Refrigerant Accumulator
→VERTICALLY MOUNTED ONLY.
→INSTALL AS CLOSE TO THE COMPRESSOR AS POSSIBLE.
→SUCTION LINE FROM EVAPORATOR INTO INLET CONNECTION INSTALLED TO
   SUCTION LINE OF COMPRESSOR.
→REVERSE CYCLE SYSTEMS REQUIRED. ACCUMULATOR TO BE INSTALLED
   BETWEEN THE COMPRESSOR AND THE REVERSING VALVE.
→KEEP DIRECT FLAME AWAY FROM FUSIBLE RELIEF DEVICE WHILE SOLDERING
   CONNECTIONS.
→SAFE WORKING PRESSURE : 450PSI.
→MAXIMUM RECOMMENDED ACTUAL TONS BASED ON PRESSURE DROP THROUGH
   ACCUMULATOR EQUIVALENT TO 1/2°F.
→MINIMUM EVAPORATOR TEMPERATURE -40°F. MINIMUM SUCTION GAS
   TEMPERATURE THROUGH ACCUMULATOR +10°F